<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-17 20-52-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 60 dBuV VOLTAGE
Pilot RDS Phase Difference
7.2 kHz 3.5 kHz 21 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 73 kHz 10060 0,0099
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
7,7 dBr 8,35 dBr 9,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 20:52, 17.01.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (61 dBuV) Max at: 73 kHz MIN: 11 kHz % above 75 kHz: 0,0099 Acquired: 2025/01/17 20:51:36 Total samples: 10060 Equivalent time: 0:08:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000
FM Scope MAX: 9,0 dBr MIN: 7,7 dBr AVE: 8,35 dBr % above 10,0 dBr: 0,0 Last value: 8,0 dBr (2025/01/17 20:51:36) Station: 96.90 MHz, signal: 5/5 (61 dBuV) 20:45 20:46 20:47 20:48 20:49 20:50 20:51 0 50 100 Dev. MAX [kHz] 0 5 10 Pm [dBr] 0 5 Signal Quality